透视立体影像分析技术在假体无菌性松动检测中的应用研究
杨涵, 雷浩, 徐彼得, 吴淏, 马寻君, 皇艳波, 毛远青, 张经纬, 王金武

Application of fluoroscopic stereophotogrammetric analysis in the detection of aseptic loosening of prostheses
YANG Han, LEI Hao, XU Bide, WU Hao, MA Xunjun, HUANG Yanbo, MAO Yuanqing, ZHANG Jingwei, WANG Jinwu
表2 算法1与算法2临床应用要求满足情况比较
Tab 2 Comparison of clinical application requirements satisfied by algorithm 1 and algorithm 2
ItemAlgorithm 1Algorithm 2
Working condition 1Working condition 2Working condition 1Working condition 2
Minimum similarity to meet clinical application requirements/%99.987/99.98499.997
Average number of registrations required to meet clinical application requirements/n16.67/5.5650.00
ry error that meets clinical application requirements/(°)0.60±0.13/0.40±0.270.81±0.50
ty error that meets clinical application requirements/mm0.59±0.24/0.06±0.040.03±0.02