Application of fluoroscopic stereophotogrammetric analysis in the detection of aseptic loosening of prostheses

  • Han YANG ,
  • Hao LEI ,
  • Bide XU ,
  • Hao WU ,
  • Xunjun MA ,
  • Yanbo HUANG ,
  • Yuanqing MAO ,
  • Jingwei ZHANG ,
  • Jinwu WANG
Expand
  • 1.Engineering Research Center of Digital Medicine and Clinical Translation, Ministry of Education of China, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China
    2.Shanghai Xuhui Excellent Medical and Industrial Intersection and Medical Artificial Intelligence Technology Innovation Center, Shanghai 200233, China
    3.School of Medicine, Shanghai University, Shanghai 200444, China
    4.School of Medical Information and Engineering, Xuzhou Medical University, Xuzhou 221004, China
    5.School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200082, China
    6.Department of Orthopaedic Surgery, Shanghai Ninth People′s Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China
WANG Jinwu, E-mail: Jinwu_wang@163.com.

Received date: 2024-01-10

  Accepted date: 2024-02-09

  Online published: 2024-09-28

Supported by

National Key R&D Program of China(2022YFF1202600);Science and Technology Innovation Action Plan of Shanghai Science and Technology Committee(22015820100);“Two-hundred Talents” Program of Shanghai Jiao Tong University School of Medicine(20152224);Translational Medicine Innovation Project of Shanghai Jiao Tong University School of Medicine(TM201613)

Abstract

Objective ·To verify the accuracy and clinical feasibility of fluoroscopic stereophotogrammetric analysis (FSA) technology based on two dimension (2D)-three dimension (3D) registration for early migration detection of aseptic loosening of joint prostheses. Methods ·2D-3D registration algorithms centering on the light source and projected object respectively in FSA technology were verified under various working conditions through image synthesis experiments, and the feasibility of clinical application was verified through real model experiments. The image synthesis experiment established a perspective projection environment with the same parameters as the real environment in a virtual environment, the 2D perspective images of the 3D model (bone or prosthesis) during the six degrees of freedom transformation were recorded, and the six degrees of freedom transformation of the 3D model was restored by using different 2D-3D registration algorithms. The error of each registration algorithm was calculated. For real model validation, the migration between bone and prosthesis after joint replacement surgery was simulated with a high precision bone prosthesis migration simulator. The 3D model of the bone or prosthesis was reconstructed by using computed tomograph (CT) images and optical scanning, and the 2D perspective images before and after prosthesis migration were captured by using a fluoroscopy device. The migration of the prosthesis was restored by using FSA technology based on 2D-3D registration, and the error of FSA technology was calculated. Results ·The accuracy of the 2D-3D registration algorithm centering on the light source was higher than that of the algorithm centering on the projected object under different working conditions. When the initial registration conditions were favorable, the algorithm centering on the light source reduced the rotation error compared to the algorithm centering on the projected object, with a statistical difference (P=0.021), and the displacement error decreases, with a significant statistical difference (P=0.000). Moreover, algorithms centering on the light sources required lower similarity and fewer registration times to meet clinical application requirements. Conclusion ·The accuracy of FSA technology based on 2D-3D registration in early migration detection of artificial joint prostheses meets clinical application requirements. This technology can warn of late aseptic loosening of prostheses by detecting early migration of prostheses after joint replacement surgery, and is expected to be applied to clinical practice through further research.

Cite this article

Han YANG , Hao LEI , Bide XU , Hao WU , Xunjun MA , Yanbo HUANG , Yuanqing MAO , Jingwei ZHANG , Jinwu WANG . Application of fluoroscopic stereophotogrammetric analysis in the detection of aseptic loosening of prostheses[J]. Journal of Shanghai Jiao Tong University (Medical Science), 2024 , 44(9) : 1061 -1068 . DOI: 10.3969/j.issn.1674-8115.2024.09.001

References

1 边焱焱, 程开源, 常晓, 等. 2011至2019年中国人工髋膝关节置换手术量的初步统计与分析[J]. 中华骨科杂志, 2020, 40(21): 1453-1460.
1 BIAN Y Y, CHENG K Y, CHANG X, et al. Reports and analysis of amount of hip and knee arthroplasty in China from 2011 to 2019[J]. Chinese Journal of Orthopaedics, 2020, 40(21): 1453-1460.
2 LEWIS P L, GRAVES S E, CUTHBERT A, et al. What is the risk of repeat revision when patellofemoral replacement is revised to TKA? An analysis of 482 cases from a large national arthroplasty registry[J]. Clin Orthop Relat Res, 2019, 477(6): 1402-1410.
3 ROOF M A, NARAYANAN S, LORENTZ N, et al. Impact of time to revision total knee arthroplasty on outcomes following aseptic failure[J]. Knee Surg Relat Res, 2023, 35(1): 15.
4 OLTEAN-DAN D, APOSTU D, TOMOAIA G, et al. Causes of revision after total hip arthroplasty in an orthopedics and traumatology regional center[J]. Med Pharm Rep, 2022, 95(2): 179-184.
5 FONTALIS A, HADDAD F S. Roentgen stereophotogrammetric analysis: still a very valuable tool in the orthopaedic research armamentarium[J]. Bone Joint Res, 2022, 11(4): 210-213.
6 XU J, SONNTAG R, KRETZER J P, et al. Model-based roentgen stereophotogrammetric analysis to monitor the head-taper junction in total hip arthroplasty in vivo: and they do move[J]. Materials, 2020, 13(7): 1543.
7 DAMMERER D, BLUM P, PUTZER D, et al. Subsidence of a metaphyseal-anchored press-fit stem after 4-year follow-up: an EBRA-FCA analysis[J]. Arch Orthop Trauma Surg, 2022, 142(8): 2075-2082.
8 DAMMERER D, BLUM P, PUTZER D, et al. Good mid-term results with the trident peripheral self-locking cup: a clinical evaluation and migration measurement with EBRA[J]. Arch Orthop Trauma Surg, 2021, 141(2): 327-332.
9 CLARKE S G, LOGISHETTY K, HALEWOOD C, et al. Low dose CT-based spatial analysis (CTSA) to measure implant migration after ceramic hip resurfacing arthroplasty (HRA): a phantom study[J]. Proc Inst Mech Eng H, 2023, 237(3): 359-367.
10 LI G A, VAN DE VELDE S K, BINGHAM J T. Validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion[J]. J Biomech, 2008, 41(7): 1616-1622.
11 ZOU D Y, TAN J Q, ZHENG N, et al. Larger medial contact area and more anterior contact position in medial-pivot than posterior-stabilized total knee arthroplasty during in-vivo lunge activity[J]. Bioengineering, 2023, 10(3): 290.
12 HU Y, ZOU D Y, JIANG M D, et al. Postoperative hip center position is associated with gait symmetry in range of axial rotation in dysplasia patients after THA[J]. Front Surg, 2023, 10: 1135327.
13 廖广姗.基于模型和图像的动态Fluoroscopic Stereophotogrammetric Analysis(FSA)技术检测人工髋关节无菌性松动的研究[D]. 上海:上海交通大学, 2013.
13 LIAO G S. A study on the detection of aseptic loosening of artificial hip joints using dynamic fluoroscopic stereographic analysis (FSA) technology based on models and images [D]. Shanghai: Shanghai Jiao Tong University, 2013.
14 廖广姗, 李慧武, 王金武, 等. 人工髋关节无菌性松动失效的生物力学分析与诊断推理[J]. 医用生物力学, 2012, 27(3): 251-257.
14 LIAO G S, LI H W, WANG J W, et al. Biomechanical analysis and reasoning on aseptic loosening failure after total hip arthroplasty[J]. Journal of Medical Biomechanics, 2012, 27(3): 251-257.
15 PRINS A H, KAPTEIN B L, STOEL B C, et al. Performance of local optimization in single-plane fluoroscopic analysis for total knee arthroplasty[J]. J Biomech, 2015, 48(14): 3837-3845.
16 FONSECA ULLOA C A, SEEGER A, HAGEDORN F S, et al. Development and validation of an algorithm to determine the minimal factors needed for non-invasive measurement of the in vivo primary stability of cementless hip implants[J]. Med Eng Phys, 2023, 111: 103932.
17 KIEVIT A J, BUIJS G S, DOBBE J G G, et al. Promising results of an non-invasive measurement of knee implant loosening using a loading device, CT-scans and 3D image analysis[J]. Clin Biomech, 2023, 104: 105930.
18 HEILEMANN M, WENDLER T, MüNST P, et al. A novel micromotion measurement method to gain instructive insight into the acetabular bone-implant interface[J]. Med Eng Phys, 2020, 86: 138-145.
Outlines

/