Basic research

Effects of nickel-titanium file systems on relationship between cleanliness and fracture resistance of long-oval root canals

  • Zhang Zhuoyang ,
  • Wang Yiwei ,
  • Chen Xiyao ,
  • Wang Ying ,
  • Sun Shuntao ,
  • Tang Zisheng
Expand
  • 1.Department of Stomatology, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200092, China
    2.Department of Stomatology, Hangzhou Children's Hospital, Zhejiang Province, Hangzhou 310005, China
TANG Zisheng, E-mail: tangzisheng163@163.com.

Received date: 2025-08-29

  Accepted date: 2025-11-13

  Online published: 2026-04-15

Supported by

National Key Research and Development Program of China(2022YFC2402105);Construction Project of the "Discipline Peak-Climbing Plan" of Xinhua Hospital, Shanghai Jiao Tong University School of Medicine(XKPF2024B50021)

Abstract

Objective ·To investigate the relationship between the cleanliness and fracture resistance of long-oval root canals using small field-of-view cone-beam CT (CBCT), computer-aided technologies, and a universal testing machine, and to explore the effects of commonly used nickel-titanium (NiTi) file systems on this relationship. Methods ·Mandibular premolars with single straight roots extracted for orthodontic reasons between April 2024 and April 2025 in the Department of Stomatology, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, were collected. CBCT was used to analyze canal morphology, and 40 teeth with long-oval canals were selected. The crowns were removed to prepare standardized root samples with a length of 13 mm. The samples were randomly and equally divided into Group A (X-GOLD, n=10), Group B (Reciproc Blue, n=10), Group C (ProTaper Universal, n=10), and a control group (n=10). Root canal preparation was performed in Groups A, B, and C using different NiTi file systems. All samples were scanned before and after preparation using CBCT, and three-dimensional models were reconstructed to calculate canal cleanliness by comparing pre- and post-preparation morphologies. The experimental groups were obturated using the single-cone technique, while the control group was left unobturated. All roots were embedded and subjected to static loading using a universal testing machine to determine fracture load. Data were analyzed to evaluate differences and trends in cleanliness and fracture resistance among the groups, and to assess their relationship. Results ·Group C showed significantly higher overall cleanliness compared to Groups A and B, and the differences were statistically significant (P<0.05), while no statistically significant difference was observed between Groups A and B (P>0.05). CBCT-based 3D reconstruction illustrated that long-oval canals tended to be over-prepared in the mesiodistal direction and under-prepared in the buccolingual direction. The control group demonstrated significantly higher fracture resistance than Groups A, B and C, and the differences were statistically significant (P<0.05). There was no statistically significant difference in the fracture load between Group A and Group B (P>0.05). Group C had significantly lower fracture resistance compared to Group A and the control group, and the difference were statistically significant (P<0.05). A significant negative correlation was found between canal cleanliness and fracture resistance in long-oval root canals (r=-0.379, P=0.039). Conclusion ·NiTi file systems affect the relationship between cleanliness and fracture resistance in long-oval root canals. In mandibular premolars with long-oval single straight canals, cleanliness is negatively correlated with fracture resistance. The ProTaper Universal NiTi file system achieves higher cleanliness while maintaining a certain level of fracture resistance in such cases.

Cite this article

Zhang Zhuoyang , Wang Yiwei , Chen Xiyao , Wang Ying , Sun Shuntao , Tang Zisheng . Effects of nickel-titanium file systems on relationship between cleanliness and fracture resistance of long-oval root canals[J]. Journal of Shanghai Jiao Tong University (Medical Science), 2026 , 46(4) : 434 -441 . DOI: 10.3969/j.issn.1674-8115.2026.04.003

References

[1] Wu M K, R'Oris A, Barkis D, et al. Prevalence and extent of long oval canals in the apical third[J]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2000, 89(6): 739-743.
[2] Papic M, Papic M, Zivanovic S, et al. The prevalence of oval-shaped root canals: a morphometric study using cone-beam computed tomography and image analysis software[J]. Aust Endod J, 2022, 48(1): 158-169.
[3] Lertchirakarn V, Palamara J E, Messer H H. Patterns of vertical root fracture: factors affecting stress distribution in the root canal[J]. J Endod, 2003, 29(8): 523-528.
[4] Velozo C, Prado V F F, Sousa I S D S, et al. Scope of preparation of oval and long-oval root canals: a review of the literature[J]. Sci World J, 2021, 2021: 5330776.
[5] Azim A A, Piasecki L, da Silva Neto U X, et al. XP shaper, a novel adaptive core rotary instrument: micro-computed tomographic analysis of its shaping abilities[J]. J Endod, 2017, 43(9): 1532-1538.
[6] Arias A, Paqué F, Shyn S, et al. Effect of canal preparation with TRUShape and Vortex rotary instruments on three-dimensional geometry of oval root canals[J]. Aust Endod J, 2018, 44(1): 32-39.
[7] Abou El Nasr H M, Abd El Kader K G. Dentinal damage and fracture resistance of oval roots prepared with single-file systems using different kinematics[J]. J Endod, 2014, 40(6): 849-851.
[8] Lin G S S, Singbal K P, Noorani T Y, et al. Vertical root fracture resistance and dentinal crack formation of root canal-treated teeth instrumented with different nickel-titanium rotary systems: an in-vitro study[J]. Odontology, 2022, 110(1): 106-112.
[9] K?l?? Y, Karata?l?o?lu E, Kaval M E. The effect of root canal preparation size and taper of middle mesial canals on fracture resistance of the mandibular molar teeth: an in vitro study[J]. J Endod, 2021, 47(9): 1467-1471.
[10] 陈君, 岳林, 王嘉德, 等. 根管扩大程度与牙根强度和应力分布的关系[J]. 中华口腔医学杂志, 2006 (11): 661-663.
  Chen J, Yue L, Wang J D, et al. The correlation between the enlargement of root canal diameter and the fracture strength and the stress distribution of root[J]. Chinese Journal of Stomatology, 2006(11): 661-663.
[11] Ossareh A, Rosentritt M, Kishen A. Biomechanical studies on the effect of iatrogenic dentin removal on vertical root fractures[J]. J Conserv Dent, 2018, 21(3): 290-296.
[12] Wang H, Yang X Q, Zou L, et al. Shaping outcome of ProTaper NEXT for root canal preparation in mandibular incisors: a micro-CT study[J]. BMC Oral Health, 2022, 22(1): 302.
[13] Patel S, Bhuva B, Bose R. Present status and future directions: vertical root fractures in root filled teeth[J]. Int Endod J, 2022, 55(Suppl 3): 804-826.
[14] Schneider S W. A comparison of canal preparations in straight and curved root canals[J]. Oral Surg Oral Med Oral Pathol, 1971, 32(2): 271-275.
[15] 王易维, 夏文君, 唐子圣, 等. 运用小视野CBCT及计算机辅助技术对3D打印椭圆形根管的预备效果评价[J]. 口腔疾病防治, 2020, 28(11): 710-713.
  Wang Y W, Xia W J, Tang Z S, et al. Evaluation of 3D-printed oval root canal preparation by small field-of-view cone beam CT and computer-aided technique[J]. Journal of Prevention and Treatment for Stomatological Diseases, 2020, 28(11): 710-713.
[16] 周学东, 陈智, 岳林, 等. 牙体牙髓病学[M]. 5版. 北京:人民卫生出版社, 2020:197-203.
  Zhou X D, Chen Z, Yue L, et al. Endodontics and operative dentistry[M]. 5th ed. Beijing: People's Medical Publishing House,2020: 197-203.
[17] Hilaly Eid G E, Wanees Amin S A. Changes in diameter, cross-sectional area, and extent of canal-wall touching on using 3 instrumentation techniques in long-oval canals[J]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2011, 112(5): 688-695.
[18] Robberecht L, Dehurtevent M, Lemaitre G, et al. Influence of root canal curvature on wall cleanliness in the apical third during canal preparation[J]. Eur Endod J, 2017, 2(1): 1-6.
[19] Baxter S, Phan K M, Hülsmann M. In vitro evaluation of root canal wall cleanliness in primary molars after preparation with Self-Adjusting-File (SAF) or Mtwo NiTi-instruments and final irrigation[J]. Eur J Paediatr Dent, 2021, 22(1): 10-14.
[20] Kfir A, Goldenberg C, Metzger Z, et al. Cleanliness and erosion of root canal walls after irrigation with a new HEDP-based solution vs. traditional sodium hypochlorite followed by EDTA. A scanning electron microscope study[J]. Clin Oral Investig, 2020, 24(10): 3699-3706.
[21] Pereira R D, Leoni G B, Silva-Sousa Y T, et al. Impact of conservative endodontic cavities on root canal preparation and biomechanical behavior of upper premolars restored with different materials[J]. J Endod, 2021, 47(6): 989-999.
[22] Bender D, Ocak M, Uzuno?lu ?zyürek E. Root canal cleanliness and debris extrusion following retreatment of thermoplastic injection technique and bioceramic-based root canal sealer[J]. Clin Oral Investig, 2024, 28(11): 608.
[23] Ordinola-Zapata R, Bramante C M, Versiani M A, et al. Comparative accuracy of the Clearing Technique, CBCT and Micro-CT methods in studying the mesial root canal configuration of mandibular first molars[J]. Int Endod J, 2017, 50(1): 90-96.
[24] Patel S, Durack C, Abella F, et al. Cone beam computed tomography in Endodontics?a review[J]. Int Endodontic J, 2015, 48(1): 3-15.
[25] Espir C G, Nascimento-Mendes C A, Guerreiro-Tanomaru J M, et al. Shaping ability of rotary or reciprocating systems for oval root canal preparation: a micro-computed tomography study[J]. Clin Oral Investig, 2018, 22(9): 3189-3194.
[26] Velozo C, Silva S, Almeida A, et al. Shaping ability of XP-endo Shaper and ProTaper Next in long oval-shaped canals: a micro-computed tomography study[J]. Int Endod J, 2020, 53(7): 998-1006.
[27] Cavalcante D M, Belladonna F G, Sim?es-Carvalho M, et al. Do pre-existing microcracks play a role in the fracture resistance of roots in a laboratory setting?[J]. Int Endod J, 2020, 53(11): 1506-1515.
[28] Fayyad D M, Elhakim Elgendy A A. Cutting efficiency of twisted versus machined nickel-titanium endodontic files[J]. J Endod, 2011, 37(8): 1143-1146.
[29] de Cristofaro Almeida G, Aun D P, Resende P D, et al. Comparative analysis of torque and apical force to assess the cutting behaviour of ProTaper Next and ProTaper Universal endodontic instruments[J]. Aust Endod J, 2020, 46(1): 52-59.
[30] Retnakaran A, Gaffoor F M A, Gopakumar R, et al. Comparative evaluation of efficiency of different endodontic file systems; protaper universal, MTWO, protaper next, trunatomy, I-race in terms of remaining dentin thickness: an In vitro CBCT analysis[J]. J Pharm Bioallied Sci, 2024, 16(Suppl 2): S1409-S1413.
[31] Caviedes-Bucheli J, Rios-Osorio N, Usme D, et al. Three-dimensional analysis of the root canal preparation with Reciproc Blue?, WaveOne Gold? and XP EndoShaper?: a new method in vivo[J]. BMC Oral Health, 2021, 21(1): 88.
[32] Bhavsar B A, Sharma P, Surana P, et al. Oval root canals prepared with two different endodontic rotary files: an in vitro study comparing the incidence of dental defects[J]. Cureus, 2023, 15(3): e35914.
[33] Devi T P, Kaur A, Priyadarshini S, et al. Microscopic assessment of dentinal defects induced by ProTaper universal, ProTaper gold, and hyflex electric discharge machining rotary file systems: an in vitro study[J]. Contemp Clin Dent, 2021, 12(3): 230-234.
[34] Koc D, Dogan A, Bek B. Bite force and influential factors on bite force measurements: a literature review[J]. Eur J Dent, 2010, 4(2): 223-232.
[35] Sathyanarayana H P, Premkumar S, Manjula W S. Assessment of maximum voluntary bite force in adults with normal occlusion and different types of malocclusions[J]. J Contemp Dent Pract, 2012, 13(4): 534-538.
Outlines

/