Clinical research

Clinical analysis of left atrial spontaneous echo contrast before and after left atrial appendage closure in patients with atrial fibrillation

  • Zhihong ZHAO ,
  • Saihua WANG ,
  • Shuwen HAO ,
  • Xiang SONG ,
  • Jun LUO ,
  • Yingbiao WU ,
  • Qian ZHU ,
  • Ming FANG ,
  • Bei TIAN ,
  • Wei GU ,
  • Zhongping NING
Expand
  • Department of Cardiology, Shanghai Pudong New Area Zhoupu Hospital, Shanghai University of Medicine & Health Sciences, Shanghai 201318, China
NING Zhongping, E-mail: ningzhongping88@163.com.

Received date: 2021-09-03

  Online published: 2022-05-09

Supported by

Shanghai Pudong Top Level Clinical Discipline Fund(PWYgf2021-04);Shanghai Key Medical Specialty Program Construction Fund(ZK2019B25);Shanghai Pudong Science and Technology Development Fund(PKJ2021-y33);Shanghai Pudong Health Committee Key Sub-Specialized Construction Fund(PWZy2020-08)

Abstract

Objective

·To investigate the occurrence of left atrial spontaneous echo contrast (LA SEC) both before and after left atrial appendage closure (LAAC) in the atrial fibrillation (AF) patients, and its relationship with device-related thrombus (DRT) and clinical prognosis.

Methods

·This study was a retrospective, cross-sectional study. A total of 126 nonvalvular AF patients receiving LAAC with LAmbre and completing transesophageal echocardiography (TEE) review were enrolled from August 2018 to December 2020 in Shanghai Pudong New Area Zhoupu Hospital, Shanghai University of Medicine & Health Sciences. The proportion of AF patients with LA SEC was 19.8% (25/126) before LAAC. The AF patients were divided into LA SEC group (n=25) and non-LA SEC group (n=101), and the clinical data, LAAC-related data, and perioperative complications were analyzed. TEE review time median was 72 d after LAAC. The patients were redivided into LA SEC group (n=58) and non-LA SEC group (n=68) for analysis. The average follow-up was (12±6) months. The incidence of DRT was compared, and the incidences of ischemic stroke and cerebral hemorrhage events were followed up.

Results

·Before LAAC, the proportion of oral anticoagulation was low, the left atrium diameter and the left ventricle diameter increased, and the left ventricle ejection fraction decreased in the LA SEC group. The incidence of LA SEC after LAAC reviewed by TEE increased to 46.0%, including 38.1% (48/126) new occurred LA SEC patients, and 40.0% (10/25) LA SEC patients with LA SEC. The redivided LA SEC group had longer left atrial appendage orifice diameter and lower application rate of anticoagulant treatment regimen. There was no significant difference in the incidence of death, ischemic stroke/transient ischemic attack, and cerebral hemorrhage between the two groups (all P>0.05).

Conclusion

·The AF patients undergoing LAAC with LA SEC before operation are characterized by low anticoagulation ratio, left atrium and left ventricle enlargement, and decreased left ventricle ejection fraction. After LAAC with LAmbre, the LA SEC patients diagnosed by TEE review have longer left atrial appendage ostium diameter and lower anticoagulant treatment regimen ratio. LA SEC does not affect the clinical prognosis.

Cite this article

Zhihong ZHAO , Saihua WANG , Shuwen HAO , Xiang SONG , Jun LUO , Yingbiao WU , Qian ZHU , Ming FANG , Bei TIAN , Wei GU , Zhongping NING . Clinical analysis of left atrial spontaneous echo contrast before and after left atrial appendage closure in patients with atrial fibrillation[J]. Journal of Shanghai Jiao Tong University (Medical Science), 2022 , 42(3) : 344 -349 . DOI: 10.3969/j.issn.1674-8115.2022.03.012

References

1 SCHOTTEN U, VERHEULE S, KIRCHHOF P, et al. Pathophysiological mechanisms of atrial fibrillation: a translational appraisal[J]. Physiol Rev, 2011, 91(1): 265-325.
2 SCHMIDT B, BORDIGNON S, CHEN S J, et al. What does the future hold?: ideal device, newer devices, and more[J]. Card Electrophysiol Clin, 2020, 12(1): 125-130.
3 SO C Y, LAM Y Y, CHEUNG G S H, et al. Occlusion of a multilobed shallow left atrial appendage using a special LAmbre device after failed Watchman implantation[J]. J Invasive Cardiol, 2019, 31(2): E41-E42.
4 中国医师协会心血管内科医师分会结构性心脏病专业委员会. 中国经导管左心耳封堵术临床路径专家共识[J]. 中国介入心脏病学杂志, 2019, 27(12): 661-672.
5 中华医学会心电生理和起搏分会, 中国医师协会心律学专业委员会. 心房颤动: 目前的认识和治疗的建议(2018)[J]. 中华心律失常学杂志, 2018, 32(4): 279-346-268.
6 ITO T, SUWA M. Left atrial spontaneous echo contrast: relationship with clinical and echocardiographic parameters[J]. Echo Res Pract, 2019, 6(2): R65-R73.
7 中华医学会心血管病学分会, 中华心血管病杂志编辑委员会. 中国左心耳封堵预防心房颤动卒中专家共识(2019)[J]. 中华心血管病杂志, 2019, 47(12): 937-955.
8 LEON M B, PIAZZA N, NIKOLSKY E, et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium[J]. J Am Coll Cardiol, 2011, 57(3): 253-269.
9 MEHRAN R, RAO S V, BHATT D L, et al. Standardized bleeding definitions for cardiovascular clinical trials: a consensus report from the Bleeding Academic Research Consortium[J]. Circulation, 2011, 123(23): 2736-2747.
10 BURSI F, SANTANGELO G, FERRANTE G, et al. Prevalence of left atrial thrombus by real time three-dimensional echocardiography in patients undergoing electrical cardioversion of atrial fibrillation: a contemporary cohort study[J]. Echocardiography, 2021, 38(4): 518-524.
11 AKAMATSU K, ITO T, OZEKI M, et al. Left atrial spontaneous echo contrast occurring in patients with low CHADS2 or CHA2DS2-VASc scores[J]. Cardiovasc Ultrasound, 2020, 18(1): 31.
12 HARADA M, KOSHIKAWA M, MOTOIKE Y, et al. Left atrial appendage thrombus prior to atrial fibrillation ablation in the era of direct oral anticoagulants[J]. Circ J, 2018, 82(11): 2715-2721.
13 WATANABE T, SHINODA Y, IKEOKA K, et al. Dabigatran exhibits low intensity of left atrial spontaneous echo contrast in patients with nonvalvular atrial fibrillation as compared with warfarin[J]. Heart Vessels, 2017, 32(3): 326-332.
14 DURMAZ E, KARADAG B, IKITIMUR B, et al. Management of periprocedural anticoagulant therapy: a novel individualized approach—a transeusophageal echocardiographic study[J]. J Thromb Thrombolysis, 2020, 50(2): 408-415.
15 SEDAGHAT A, NICKENIG G, SCHRICKEL JW, et al. Incidence, predictors and outcomes of device-related thrombus after left atrial appendage closure with the WATCHMAN device: insights from the EWOLUTION real world registry[J]. Catheter Cardiovasc Interv, 2021, 97(7): E1019-E1024.
16 WANG G J, KONG B, QIN T Y, et al. Incidence, risk factors, and clinical impact of peridevice leak following left atrial appendage closure with the LAmbre device: data from a prospective multicenter clinical study[J]. J Cardiovasc Electrophysiol, 2021, 32(2): 354-359.
Outlines

/