上海交通大学学报(医学版) ›› 2018, Vol. 38 ›› Issue (11): 1337-.doi: 10.3969/j.issn.1674-8115.2018.11.012

• 论著·临床研究 • 上一篇    下一篇

QGS和ECTb软件在门控心肌灌注显像定量分析中的比较

宋结平,寿毅,姜建隽,尤志雯,孟庆元,赵军   

  1. 同济大学附属东方医院核医学科,上海 200120
  • 出版日期:2018-11-28 发布日期:2018-12-15
  • 通讯作者: 赵军,电子信箱:petcenter@126.com。
  • 作者简介:宋结平(1989—),男,主治医师,硕士;电子信箱: jiepingsong@126.com。
  • 基金资助:
    上海市浦东新区卫生系统重点专科建设项目(PWZzk2017-24)

Comparison of quantitative analysis between QGS and ECTb software programs used in gated myocardial perfusion imaging

SONG Jie-ping, SHOU Yi, JIANG Jian-jun, YOU Zhi-wen, MENG Qing-yuan, ZHAO Jun   

  1. Department of Nuclear Medicine, East Hospital, Tongji University, Shanghai 200120, China
  • Online:2018-11-28 Published:2018-12-15
  • Supported by:
    Key Specialty Construction Project of Pudong Health and Family Planning Commission of Shanghai, PWZzk2017-24

摘要: 目的 ·探讨单光子发射计算机断层成像( single-photon emission computed tomography,SPECT)门控心肌灌注显像( gated myocardial perfusion imaging,G-MPI)中常用的 2种处理软件 Cedars-Sinai定量门控 SPECT(quantitative gated SPECT,QGS)和爱莫瑞心脏工具箱( Emory cardiac toolbox,ECTb)所得定量分析结果的差异。方法 ·回顾性分析以锝 -99m-甲氧基异丁基异腈( 99mTcmethoxyisobutylisonitrile, 99mTc-MIBI)为心肌灌注显像剂进行 SPECT G-MPI的 28例患者(共 37人次)的检查结果,使用 QGS和 ECTb 2种后处理软件分别对心功能参数 [左心室射血分数( left ventricular ejection fraction,LVEF)、舒张末期容积( end-diastolic volume,EDV)和收缩末期容积( end-systolic volume,ESV)]及相位分析参数 [相位直方图带宽( phase histogram bandwidth,PHB)和相位标准差( phase standard deviation,PSD)]进行定量分析。并分析同一参数在 2种软件处理结果中的相关性及差异。结果 · 2种软件所测得 LVEF、EDV和 ESV值的相关性较好( LVEF:r0.917,P0.000。EDV:r0.976,P0.000。ESV:r0.981,P0.000)。但 2种软件进行相位分析所得 PHB及 PSD的相关性均不明显( PHB:r0.319,P0.055。PSD:r0.172,P0.310)。在心功能分析方面, QGS所测得 ESV值高于 ECTb所测得值,而 QGS所测得 EDV、LVEF值则均低于 ECTb所测得值。在相位分析方面, QGS所测得 PSD、PHB值均低于 ECTb所测得值。分析 2种软件所测结果之间的差异,发现 2种软件所测得 LVEF、ESV、PSD值的差异有统计学意义 [LVEF:(47.8±16.9)% vs(57.4±17.2)%,P0.000。ESV:(67.5±51.0) mL vs(58.3±50.0)mL,P0.000。 PSD:20.5o±10.3o vs 30.6o±18.9o,P0.004]。而 2种软件所测得 EDV、PHB值的差异无统计学意义 [EDV:(116.8±52.8) mL vs(120.8±55.7)mL,P0.050。PHB:72.2o±37.0o vs 86.1o±55.7o,P0.139]。结论 · QGS与 ECTb 软件在 G-MPI定量分析中所测得左心功能参数的相关性好,但 2种软件在左心室机械不同步评估(相位分析)中无明显相关性。 2种软件所测得同一参数的值之间有差异,故在临床应用中 2种软件所测得结果不适合直接对比参考。 2种软件所测得结果的差异提示,在临床工作中有必要根据科室所用软件建立本单位正常人群的数据库。

关键词: 门控心肌灌注显像, 定量分析, 软件, 心功能

Abstract:

Objective · To study the differences and correlations of quantitative analysis between Cedars-Sinai quantitative gated SPECT (QGS) and Emory cardiac toolbox (ECTb) used in single photon emission computed tomography (SPECT) gated myocardial perfusion imaging (G-MPI). Methods · A total of 28 patients were examined with 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) SPECT G-MPI. The left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), end-systolic volume (ESV), phase histogram bandwidth (PHB) and phase standard deviation (PSD) were calculated with QGS and ECTb. The correlations and differences of the results these two programs were analyzed. Results · These two software programs showed high correlation for LVEF, EDV and ESV (LVEF: r0.917, P0.000. EDV: r0.976, P0.000. ESV: r0.981, P0.000). The analysis showed no significant correlation for PHB and PSD (PHB: r0.319, P0.055. PSD: r0.172, P0.310). In the analysis of cardiac function, the ESV measuredQGS was higher than that measuredECTb, and the EDV and LVEF were lower than those measuredECTb. In the phase analysis, the PSD and PHB measuredQGS were lower than those measuredECTb. These differences between the results measuredthe two software programs were not consistency. There were significant differences in LVEF, ESV and PSD in the comparison of QGS and ECTb [LVEF: (47.8±16.9)% vs (57.4±17.2)%, P0.000. ESV: (67.5±51.0) mL vs (58.3±50.0) mL, P0.000. PSD: 20.5o±10.3o vs 30.6o±18.9o, P 0.004]. The EDV and PHB showed no significant difference between the QGS and ECTb [EDV: (116.8±52.8) mL vs (120.8±55.7) mL, P0.050. PHB: 72.2o±37.0o vs 86.1o±55.7o, P0.139]. Conclusion · These two software programs have good consistency in quantitative analysis of cardiac function. But the result shows no significant consistent in the evaluation of left ventricular mechanical dyssynchrony. There are differences between the data measuredQGS and ECTb. Using the results measuredthe two software programs for direct comparison may be not suiin clinical applications. The differences between these two software programs indicate that it may be necessary to establish a normal databases in clinical work based on the local conditions.

Key words: gated myocardial perfusion imaging, quantitative analysis, software, cardiac function

中图分类号: